Description
Vida Armour 1200VA Line-Interactive UPS (720W) with LCD Display, AVR & 6 Outlets
The Vida Armour 1200VA UPS is a reliable line-interactive uninterruptible power supply designed to protect PCs, office equipment, routers and CCTV systems from power cuts, brownouts and voltage spikes. With a 1.2kVA / 720W capacity, built-in Automatic Voltage Regulation (AVR), fast transfer time and clear LCD status display, it helps keep your equipment running safely and gives you time to save work and shut down properly during outages.
It’s ideal for home offices, small businesses and system-integrator builds where stable power and surge protection reduce downtime and hardware risk—especially in areas with unstable mains supply.
Summary
Vida Armour 1200VA (720W) is a line-interactive UPS with AVR, LCD display, 6 total outlets (UK + IEC), and USB monitoring, providing battery backup and voltage regulation for PCs and networking gear. It uses 2× 12V 7Ah sealed lead-acid batteries, supports DC cold start, and includes RJ45 in/out protection for network lines.
Key Features & Benefits
- 1200VA / 720W capacity – suitable for desktops, monitors, NAS, routers and small office loads
- Line-interactive topology + AVR – helps stabilise voltage without switching to battery as often
- Fast transfer time – switches to battery in ≤ 6ms (typical spec)
- LCD + LED indicators – quick view of power, battery, load and fault status
- 6 outlet total – 3× UK mains sockets + 3× IEC sockets for flexible connections
- USB monitoring – connect to a PC for monitoring/shutdown via software
- RJ45 surge protection (in/out) – helps protect network-connected devices from line surges
- DC cold start – start the UPS on battery power when mains is unavailable
Performance & Protection
Battery Backup Runtime
Backup time is load-dependent; typical listings quote around 15–20 minutes depending on connected equipment and power draw—ideal for safely saving work and shutting down.
The UPS uses 2× 12V 7Ah maintenance-free sealed lead-acid batteries, with recharge to ~90% capacity in around 8 hours (typical spec).
Surge + Voltage Protection
Designed for everyday protection, it includes surge and voltage safeguards such as over/under-voltage protection and surge protection, plus a relay cut-off feature noted in supplier specs.
Connections & I/O
Outlets
- 3× UK mains sockets
- 3× IEC outlets
Monitoring & Line Protection
- USB monitoring port for PC connection
- 2× RJ45 (In/Out) network line protection
Specifications at a Glance
- Capacity: 1200VA / 720W
- Topology: Line-interactive
- Transfer time: ≤ 6ms
- Input/Output voltage: 230/240VAC (listed)
- Battery: 2× 12V 7Ah sealed lead-acid
- Recharge: ~90% in ~8 hours (listed)
- Noise: up to ~45dB at 1m (listed)
- Operating environment: 0–40°C, 20–90% humidity (non-condensing)
- Dimensions (WxHxD): 125 × 225 × 320 mm
- Weight: ~10.7 kg
- Warranty: 1 year (listed)
- EAN (listed): 5056733100505
Compatibility Notes
- Check total watts: keep your combined load under 720W for stable backup operation.
- Runtime varies by load: higher loads reduce backup minutes significantly.
- For long runtimes: this model is best for safe shutdown and short backup periods rather than hours of operation.
Specification
Features
UPS topology
The two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
Line-Interactive
Output power capacity
The maximum power that the device can produce.
1.2 kVA
Output power
The power that the device can produce.
720 W
Waveform
Sine/Square
Input operation voltage (min)
The minumum voltage needed by the device during operation.
230 V
Input operation voltage (max)
The maximum input voltage supported by the device.
240 V
Output operation voltage (min)
The minumum voltage produced by the device during operation.
230 V
Output operation voltage (max)
The maximum output voltage produced by the device.
240 V
Transfer time (Line Mode to Battery Mode)
6 ms
Noise level
The amplitude level of the undesired background noise, usually measured in decibels (db).
45 dB
Surge protection
Power protection features
Features that protect the device against power problems e.g. overload.
Over voltage, Under voltage
Audible alarm(s)
Alarms that make a sound when they are activated (set off).
Ports & interfaces
AC outlet types
The type of outlet for AC electricity.
C13 coupler, Type G (BS 1363)
Power plug
A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
Type G
AC outlets quantity
The number of sockets in the device where AC electrical power can be connected.
6 AC outlet(s)
USB port
The device features a socket into which a USB cable can be plugged.
USB port type
USB Type-B
Ethernet LAN (RJ-45) ports
Number of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
2
Battery
Battery technology
The type of battery in the device, e.g. nickel–cadmium (NiCd).
Sealed Lead Acid (VRLA)
Battery capacity
The amount of electric charge a battery can deliver at the rated voltage. The more electrode material contained in the cell the greater its capacity. A small cell has less capacity than a larger cell with the same chemistry, although they develop the same open-circuit voltage. Capacity is measured in units such as amp-hour (A·h).
7 Ah
Battery voltage
The voltage (V) of the battery.
12 V
Number of batteries supported
The number of batteries that can be used with the product.
2
Number of batteries included
The quantity of batteries that come with the product.
2 pc(s)
Battery
Battery recharge time
Approximate time required to recharge the battery from completely empty to completely full
8 h
Cold start
Design
Form factor
The shape or design of the product.
Desktop
Product colour
The colour e.g. red, blue, green, black, white.
Black
Display type
Type of display (screen) e.g. LCD.
LCD
LED indicators
Operational conditions
Operating temperature (T-T)
The minimum and maximum temperatures at which the product can be safely operated.
0 - 40 °C
Operating relative humidity (H-H)
20 - 90%
Certificates
Compliance certificates
UKCA, CE
Packaging content
Cables included
USB cable
Manual
Weight & dimensions
Width
The measurement or extent of something from side to side.
125 mm
Depth
The distance from the front to the back of something.
320 mm
Height
The measurement of the product from head to foot or from base to top.
225 mm
Weight
Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
10.7 kg
Packaging data
Package width
The distance from one side of the packaging to the other.
180 mm
Package depth
The distance from the front to the back of the packaging.
390 mm
Package height
The distance from the top to the bottom of the packaging.
295 mm
Package weight
Weight of the packaged product.
11.1 kg
Package type
The type of product package e.g. box.
Box
Logistics data
Country of origin
Country where the device is made. Aka Country of manufacture (COM).
China
Return
FAQ: Frequently Asked Questions
VIDA Armour 1200VA UPS (1.2kVA / 720W) — FAQ
What is the VIDA Armour 1200VA UPS?
What does 1200VA / 720W mean—and how do I size it?
How long will it run during a power cut?
Is it line-interactive and does it have AVR?
How fast is the switchover to battery (transfer time)?
What waveform does it output on battery?
How many outlets does it have, and what types?
Does it have USB monitoring and surge protection?
Does it protect network/phone lines (RJ45)?
Can it start without mains power (cold start)?
What batteries does it use, and can they be replaced?
How long does it take to recharge?
Will it work with a generator?
What are the dimensions, weight, and noise level?
Why is my UPS beeping?
- On battery (power cut) — it alerts you to save and shut down.
- Overload — load is too high for 720W; unplug non-essential devices.
- Battery needs replacing — reduced runtime, frequent alarms, or won’t hold charge.